PLEASE BE ADVISED THAT WE ARE CURRENTLY EXPERIENCING ISSUES WITH OUR INCOMING TELEPHONE SYSTEM.

IF YOU ARE UNABLE TO REACH US BY TELEPHONE, PLEASE USE THE EMAIL ADDRESSES ON THE CONTACT PAGE OR FILL IN THE CONTACT FORM AND ONE OF OUR TEAM MEMBERS WILL GET BACK TO YOU.

Products

PRODUCT LINES

Products - Power Supplies

» General Purpose » Reversible PSU's » Fast Switching » Custom Designs

Applications

» Mass Spectrometry » X-Ray » Electron / Ion Beam » SEM » Nuclear Instruments » Capacitor Charging » Photomultipliers » Electrostatics » Detectors

LTR Series

Precision High Voltage Modules

LT001, LT2.5, LT005, LT010, LT015, LT020, LT030

Applications: Mass spectrometers, Electron microscopes, Nuclear instruments, Photomultiplier tubes, Microchannel plates

  • 1kV, 2.5kV, 5kV, 10kV, 15kV, 20kV, 30kV
  • Highest Stability, Lowest Ripple, Lowest Drift
  • Externally programmable or Internal control (option)
  • Short circuit and flashover proof
  • 24 hour burn in
  • Low radiated magnetic field
  • Positive, negative & remote reversible versions

The LT Series builds on the new standard for high voltage precision and stability set by the LS 1W family. By optimising the Low Stress™ technologies pioneered in the LS family, the LT Series provides 3W o/p capability, but still has less than 2ppm ripple, 10ppm/°C temperature coefficient, and 75ppm drift/hr throughout the range, while retaining the same LS case dimensions.

Each of the units includes a differential control input.

All units are short circuit proof and use proven techniques to drive a high frequency oscillator and ferrite high voltage step-up transformer. These advanced power supplies build on Applied Kilovolts’ legendary reputation for reliability, being constructed from conservatively rated components with their reliability further enhanced by information gained over many years of field operation.

Available as +ve or -ve up to 50kV, and electrically reversible at voltages up to 30kV.

Please see the HPZ range for zero crossing reversible (bi-polar) units.

We manufacture a large number of customized OEM versions and would be pleased to discuss your application with you.

Electrical Specification Positive & Negative Polarity Units
Unit Type Polarity Output Ripple at Full Load Size (mm)
LT001PIP010 Positive 10 volts to 1kV at 3mA 2mV peak to peak 156x127x64
LT001NIP010 Negative
LT2.5PIP010 Positive 10 volts to 2.5kV at 1.2mA 5mV peak to peak 156x127x64
LT2.5NIP010 Negative
LT005PIP010 Positive 10volts to 5kV at 600uA 10mV peak to peak 156x127x64
LT005NIP010 Negative
LT010P IP010 Positive 20 volts to 10kV at 300uA 20mV peak to peak 156x127x64
LT010N IP010 Negative
LT015P IP010 Positive 30 volts to 15kV at 200uA 30mV peak to peak 207x148x74
LT015N IP010 Negative
LT020P IP010 Positive 50 volts to 20kV at 150uA 40mV peak to peak 207x148x74
LT020N IP010 Negative
LT030P IP010 Positive 100 volts to 30kV at 100uA 60mV peak to peak 207x148x74
LT030N IP010 Negative
Electrical Specification Reversible Polarity Units
Unit Type Polarity Output Ripple At Full Load Size (mm)
LT001RIP010 REVERSIBLE ±10V to ±1kV at 3mA 2mV peak to peak 163x152x71.5
LT2.5RIP010 REVERSIBLE ±10V to ±2.5kV at 1.2mA 5mV peak to peak 163x152x71.5
LT005RIP010 REVERSIBLE ±10V to ±5kV at 600uA 10mV peak to peak 163x152x71.5
LT010RIP010 REVERSIBLE ±20V to ±10kV at 300uA 20mV peak to peak 163x152x71.5
LT015RIP010 REVERSIBLE ±30V to ±15kV at 200uA 30mV peak to peak 233x204x114
LT020RIP010 REVERSIBLE ±50V to ±20kV at 150uA 40mV peak to peak 233x204x114
LT030RIP010 REVERSIBLE ±100V to ±30kV at 100uA 60mV peak to peak 233x204x114
Input Voltage +24 volt d.c. ±10% at <500mA, for Unipolar, and at <600mA for Reversibles. Negative input terminal common to HV earth return..
Output Voltage See tables above.
Line Regulation Less than 4 ppm of maximum voltage for input changes of 1 volt.
Load Regulation Less than 10ppm for load changes from 10% to 100%.
(Measured at maximum voltage).
Overload Protection Flashover and short circuit proof. Re-entrant current limit.
Temperature Coefficient <10ppm/ oC from 20oC to 50 oC
Drift
<75ppm per hour (<0.005%)
<150ppm per 8 hours (<0.01%)
Measured at constant input voltage, load current & ambient temperature after 0.5 hour warm up.
Control 10V analogue signal. (0 to +10V gives zero to maximum output, tolerance ±2%, -1/2%). Input impedance > 100Kohm.
EXTERNAL potentiometer = Option Code PP INTERNAL potentiometer = Option Code FP
Readout Voltage monitor: 0 to +10V represents zero to maximum output, tolerance ±2% (Zout=10k).
Precision Current Monitor: 0 to 10V represents zero to 100% o/p current, ±2%, Offset ±0.1% of FS (Zout=10k)
Operating Temperature 0°C to +50°C
Storage Temperature -35°C to +85°C
R.F.I. Steel case for low radiated magnetic field.
Mechanical Specification
Fixings Blind Fasteners into the base.
Output By 1 meter screened cable, or optional integrated high voltage connector N.B. Reducing the cable length may increase the ripple voltage.
Input Connector 15 way D-type
e.g. Order Code: LT010NIP010 = negative 10kV unit,
LT005PPP010 = positive 5kV unit for control by External Potentiometer.