Input: |
+24 volt dc ±10% <1A. 0V input common to HV return and chassis. |
Output, voltage / current |
See table above. |
Ripple: |
<0.1% p/p |
Line regulation: |
<300ppm of rated output for ±10% input change. |
Load regulation: |
<0.5% at rated output. |
Temperature coefficient: |
<100ppm/oC at rated output |
Drift (after 1 hour warm up): |
100ppm per hour, 200ppm per 8 hours. |
Control: V for CV and C for CC option |
0 to +5V analogue input for rated negative or positive output, accuracy ±2%, Zin 100K. |
Compliance input: Current for CV option,
Voltage for CC option |
0 to +5V analogue input for rated output, accuracy ±2%, Zin 100K. User accessible preset
potentiometer, 0 to +5.1V available (pin 3). |
Mode input (RCD types): |
TTL: Hi = constant voltage, Lo = constant current, internal +5V pull up. |
Voltage & Current monitors: |
0 to +5V (*10V for nA types) for rated negative or positive output, accuracy ±2%, Zout 10K. |
Polarity input |
TTL: Hi = +ve, Lo = -ve, internal +5V pull up. |
Safety |