power supplies, scientific instruments scientific instruments
Manufacturer of high voltage power supplies
power supplies, photomultiplier tubes
PRODUCTS | COMPANY PROFILE | FAQ's | CAREERS | NEWS & EVENTS | SUPPORT | CONTACT US | HOME

 

LT001, LT2.5, LT005, LT010,
LT015, LT020, LT030

Precision High Voltage Modules

Applications (3 Watt max)

  • Mass spectrometers
  • Electron microscopes
  • Nuclear instruments
  • Photomultiplier tubes
  • Microchannel plates

Features

  • 1kV, 2.5kV, 5kV, 10kV, 15kV, 20kV, 30kV
  • Highest Stability, Lowest Ripple, Lowest Drift
  • Externally programmable or Internal control (option)
  • Short circuit and flashover proof
  • 24 hour burn in
  • Low radiated magnetic field
  • Positive, negative & remote reversible versions

The LT Series builds on the new standard for high voltage precision and stability set by the LS 1W family. By optimising the Low Stress™ technologies pioneered in the LS family, the LT Series provides 3W o/p capability, but still has less than 2ppm ripple, 10ppm/°C temperature coefficient, and 75ppm drift/hr throughout the range, while retaining the same LS case dimensions .

Each of the units includes a differential control input.

All units are short circuit proof and use proven techniques to drive a high frequency oscillator and ferrite high voltage step-up transformer. These advanced power supplies build on Applied Kilovolts’ legendary reputation for reliability, being constructed from conservatively rated components with their reliability further enhanced by information gained over many years of field operation.

Available as +ve or -ve up to 50kV, and electrically reversible at voltages up to 30kV.

Please see the HPZ range for zero crossing reversible (bi-polar) units.

We manufacture a large number of customized OEM versions and would be pleased to discuss your application with you.


Electrical Specification
Positive & Negative Polarity Units

Unit Type Polarity Output

Ripple at Full Load

Size (mm)
LT001PIP010

Positive

10 volts to 1kV at 3mA

2mV peak to peak

156x127x64

LT001NIP010

Negative

LT2.5PIP010

Positive

10 volts to 2.5kV at 1.2mA

5mV peak to peak

156x127x64

LT2.5NIP010

Negative

LT005PIP010

Positive

10volts to 5kV at 600uA

10mV peak to peak

156x127x64

LT005NIP010

Negative

LT010P IP010

Positive

20 volts to 10kV at 300uA

20mV peak to peak

156x127x64

LT010N IP010

Negative

LT015P IP010

Positive

30 volts to 15kV at 200uA

30mV peak to peak

207x148x74

LT015N IP010

Negative

LT020P IP010

Positive

50 volts to 20kV at 150uA

40mV peak to peak

207x148x74

LT020N IP010

Negative

LT030P IP010

Positive

100 volts to 30kV at 100uA

60mV peak to peak

207x148x74

LT030N IP010

Negative


Electrical Specification
Reversible Polarity Units

UNIT TYPE

POLARITY

OUTPUT

RIPPLE AT FULL LOAD

SIZE (mm)

LT001RIP010

REVERSIBLE

±10V to ±1kV at 3mA

2mV peak to peak

163x152x71.5

LT2.5RIP010

REVERSIBLE

±10V to ±2.5kV at 1.2mA

5mV peak to peak

163x152x71.5

LT005RIP010

REVERSIBLE

±10V to ±5kV at 600uA

10mV peak to peak

163x152x71.5

LT010RIP010

REVERSIBLE

±20V to ±10kV at 300uA

20mV peak to peak

163x152x71.5

LT015RIP010

REVERSIBLE

±30V to ±15kV at 200uA

30mV peak to peak

233x204x114

LT020RIP010

REVERSIBLE

±50V to ±20kV at 150uA

40mV peak to peak

233x204x114

LT030RIP010

REVERSIBLE

±100V to ±30kV at 100uA

60mV peak to peak

233x204x114


INPUT VOLTAGE: +24 volt d.c. ±10% at <500mA, for Unipolar, and at <600mA for Reversibles.
Negative input terminal common to HV earth return..
OUTPUT VOLTAGE: See tables above.
LINE REGULATION: Less than 4 ppm of maximum voltage for input changes of 1 volt.
LOAD REGULATION: Less than 10ppm for load changes from 10% to 100%.
(Measured at maximum voltage).
OVERLOAD PROTECTION: Flashover and short circuit proof. Re- entrant current limit.
TEMPERATURE COEFFICIENT: <10ppm/ oC from 20oC to 50 oC
DRIFT:
<75ppm per hour (<0.005%)
<150ppm per 8 hours (<0.01%)
Measured at constant input voltage, load current & ambient temperature after 0.5 hour warm up.
CONTROL: 10V analogue signal. (0 to +10V gives zero to maximum output, tolerance ±2%, -1/2%). Input impedance > 100Kohm.
EXTERNAL potentiometer = Option Code PP INTERNAL potentiometer = Option Code FP
READOUT: Voltage monitor: 0 to +10V represents zero to maximum output, tolerance ±2% (Zout=10k).
Precision Current Monitor: 0 to 10V represents zero to 100% o/p current, ±2%, Offset ±0.1% of FS (Zout=10k)
OPERATING TEMPERATURE: 0°C to +50°C
STORAGE TEMPERATURE: -35°C to +85°C
R.F.I.: Steel case for low radiated magnetic field.

Mechanical Specification

FIXINGS:

Blind Fasteners into the base.

OUTPUT:

By 1 metre screened cable, or optional integrated high voltage connector
N.B. Reducing the cable length may increase the ripple voltage.
INPUT CONNECTOR: 15 way D-type
e.g. Order Code: LT010NIP010 = negative 10kV unit,
LT005PPP010 = positive 5kV unit for control by External Potentiometer.