- NOW OBSOLETE -
Not to be used for new designs. Will not be available after 31/12/2003
|
KW1/250, KW2.5/100, KW5/50, KW10/25, KW15/16
HIGH POWER 250W HIGH VOLTAGE MODULES
- 1kV, 2.5kV, 5kV, 10kV & 15kV
- High efficiency
- Off line, high frequency switch mode control
- Internal control or externally programmable
- Short circuit and flashover proof
- 24 hour burn in
- Low radiated magnetic field
|

[Click image to enlarge]
|
|
Pin Connection & Safety Instructions
|
ELECTRICAL SPECIFICATION
|
|
UNIT TYPE
|
POLARITY
|
OUTPUT
|
RIPPLE AT FULL LOAD
|
|
KW1/250P
|
POSITIVE
|
50 volts to 1kV at 250mA
|
<0.25% peak to peak
|
|
KW1/250N
|
NEGATIVE
|
|
KW2.5/100P
|
POSITIVE
|
100volts to 2.5kV at 100mA
|
<0.25% peak to peak
|
|
KW2.5/100N
|
NEGATIVE
|
|
KW5/50P
|
POSITIVE
|
250volts to 5kV at 50mA
|
<0.25% peak to peak
|
|
KW5/50N
|
NEGATIVE
|
|
KW10/25P
|
POSITIVE
|
500 volts to 10kV at 25mA
|
<0.25% peak to peak
|
|
KW10/25N
|
NEGATIVE
|
|
KW15/16P
|
POSITIVE
|
750 volts to 15kV at 16mA
|
<0.25% peak to peak
|
|
KW15/16N
|
NEGATIVE
|
|
|
INPUT VOLTAGE:
|
200 to 264V ac 50/60 Hz at 4.5A rms (110V option to special
order).
|
|
OUTPUT VOLTAGE:
|
See separate table.
|
|
LINE REGULATION:
|
Less than 0.1% of maximum voltage for input changes of 10%.
|
|
LOAD REGULATION:
|
Less than 0.1% of maximum voltage for load changes from 10%
to maximum.
|
|
OVERLOAD PROTECTION:
|
Flashover and short circuit proof. Current trip level variable
by internal potentiometer, external potentiometer or by analogue
signal such that 0 to +10V sets 0 to maximum trip level.
|
|
TEMPERATURE CO-EFFICIENT:
|
300ppm/ °C or better.
|
|
CONTROL:
|
- INTERNAL potentiometer.
- EXTERNAL potentiometer or 10V analogue signal. (0 to +10V
gives zero to maximum output, tolerance +2%). Input impedance
> 100Kohm.
|
|
VOLTAGE MONITOR:
|
0 to +10V represents zero to maximum voltage, source resistance
10 kohm.
|
|
CURRENT MONITOR:
|
0 to +10V represents zero to maximum current, source resistance
10 kohm.
|
|
OPERATING TEMPERATURE:
|
0 °C to +45 °C
|
|
STORAGE TEMPERATURE:
|
-35 °C to +85 °C
|
|
R.F.I.:
|
To EN55011.
|
|
SAFETY:
|
To EN61010-1.
|
|
MECHANICAL SPECIFICATION
|
|
SIZE:
|
All units 365 x 220 x 76mm.
|
|
OUTPUT:
|
By 0.5 metre screened cable. N.B. Reducing the cable length
may increase the ripple voltage.
|
|
INPUT:
|
Mains lead 2 metres long, control by D-type connector.
|
|