Low ripple high voltage power supplies

HF3 Series

3.5 kV FLOATING MICROCHANNEL PLATE POWER SUPPLIES AT UP TO 30 kV ISOLATION

Applications

  • Microchannel plates for Mass Spectrometers & Electron Microscopes
  • Floating grid & bias voltages
floating microchannel plates

[Click image to enlarge]


These power supplies, based on the standard HP series are intended to power imaging detectors. They give 0 to +3.5kV and can be floated on voltages up to ±2.5kV (HFxx2.5), ±10kV (HFxx010), ±20kV (HFxx020) & ±30kV (HFxx030) and use differential feedback techniques to allow the 24 volt power, control and monitor signals to be at ground potential.


Pin Connection & Safety Instructions


ELECTRICAL SPECIFICATION

UNIT TYPE

OUTPUT

ISOLATION

OUTPUT RIPPLE

INJECTED RIPPLE (1)

HF003PAA2.5
HF003PAL2.5

0 TO +3.5kV
at 1 ma

±2.5 kV (2)

50 mV peak to peak

50 mV peak to peak
25 mV peak to peak

HF003PAA010
HF003PAL010

0 TO +3.5kV
at 1 ma

±10 kV (3)

75 mV peak to peak

75 mV peak to peak
35 mV peak to peak

HF003PAA020
HF003PAL020

0 TO +3.5 kV
at 1 ma

±20 kV (3)

100 mV peak to peak

150 mV peak to peak
75 mV peak to peak

HF003PAA030

0 TO +3.5 kV
at 1 ma

±30 kV (3)

150 mV peak to peak

200 mV peak to peak


(1) ripple injected into the power supply providing the floating voltage, measured assuming load capacitance of 1000 pF.
(2) resistance to ground 400 Mohm on each output.
(3) resistance to ground 600 Mohm on each output.

AA= Option Code:
AA=Standard Unit, PR=Pot & Ref Ctrl, PL=Pot & Ref Ctrl + Low Injected Ripple option
AL=Low Injected Ripple Option, but Pot & Ref Ctrl Option Not Fitted


ELECTRICAL SPECIFICATION

Input voltage:

+24 volt at 0.7 amp

Output voltage:

See table above for output voltage and isolation voltage.

Control:
(At Ground Level)

0 to +10V gives 0 to +3.5 kV. Tolerance ±3%, input impedance >100 kohm.
INTERNAL or EXTERNAL potentiometer control Optional - Option Code P

Line regulation:

Less than 0.1%.

Load regulation:

Less than 0.1%.

Voltage monitor:

0 to +10V ±3% represents 0 to +3.5 kV.
Source resistance 10 kohm.

Drift:

Typically 0.1% of full scale voltage per hour, measured at constant input voltage, output voltage, load, polarity & ambient temperature after 1 hours warm up.

Temperature co-efficient:

Less than 0.02% per °C.

Operating temperature:

0 °C to +50 °C.

MECHANICAL SPECIFICATION

Size:

210 x 120 x 60mm

Input:

Molex connector. (24V power, control and monitor are all at ground potential).

Floating output:

By twin flying screened (shielded) leads type URM43 isolation up to 10kV, TV30 (HFxx20/30)

 

Download PDF

Download PDF:

Data Sheet | Installation Notes | Outline Drawing |

 

Top | Detailed Photo | Installation Notes

 