precision power supplies
PRODUCTS | COMPANY PROFILE | FAQ's | CAREERS | NEWS & EVENTS | SUPPORT | CONTACT US | HOME
 

SAFETY & INSTALLATION INSTRUCTIONS FOR HP & KS SERIES FITTED WITH CURRENT MONITOR

Precision Current Monitor

Units fitted with the optional precision current monitor have the circuit shown below fitted internally and give 0 to 10V to represent 0 to maximum current. The information below does not apply to units fitted with precision current monitor and if unused a resistor is not required from pin 8 to pin 9.

Simple Current Monitor

For units fitted with a simple stack return type current monitor, current is measured between pin 8 (HPR reversible units use pin 1 instead) and pin 9 (0 volt). The polarity of the voltage on pin 8 is opposite to the unit polarity. IF UNUSED PIN 8 SHOULD BE JOINED TO PIN 9, IF THIS IS NOT DONE THE INTERNAL NEON BULB WILL FLASH PERIODICALLY.

Protection during arcing is by an internal 1.0 uF capacitor and neon bulb. If a resistor is fitted between pins 8 (HPR units pin 1) & 9 then a voltage of up to 50 volts will be produced. A high voltage may degrade the load regulation of the unit.

The current measured includes internal feedback currents used to control the unit. These currents are proportional to the output voltage and are 100 uA on the HP series (except HP10P, HP10N, HP10R = 50 uA, HP20P, HP20N & HP20R = 33 uA & HP30P, HP30N & HP30R= 50 uA) and 50 uA on the KS series.

 

Unit type and output voltage

Load current

Measured current on simple current monitor

HP series at full voltage *

0 uA

100 uA

HP series at half voltage *

0 uA

50 uA

HP series at full voltage *

10 uA

110 uA

HP series at half voltage *

10 uA

60 uA

KS series at full voltage

0 uA

50 uA

KS series at half voltage

0 uA

25 uA

KS series at full voltage

10 uA

60 uA

KS series at half voltage

10 uA

35 uA


* Except HP10P, HP10N, HP10R, HP20P, HP20N, HP20R, HP30P & HP30N, HP30R.

The I monitor signal can be used in 3 ways:

1/ Remove the feedback current by calculation.

2/ Feeding the signal to a computer which can compute the actual current from the output voltage.

3/ Feedback back-off circuit see diagram below.


SIMPLE CURRENT MONITOR

METER READS ACTUAL CURRENT PLUS INTERNAL FEEDBACK CURRENT (HP SERIES 100 uA, KS SERIES 50 uA AT FULL OUTPUT)

 

 

CURRENT MONITOR WITH INTERNAL FEEDBACK CURRENT REMOVED

POSITIVE POLARITY UNITS

 

 

CURRENT MONITOR WITH INTERNAL FEEDBACK CURRENT REMOVED

NEGATIVE POLARITY UNITS

 

NOTES

1/ R6 & R16 TOTAL 100K INCLUDING 10K SOURCE RESISTANCE. FOR ACCURATE MEASUREMENTS OF LESS THAN 1uA REPLACE WITH POTENTIOMETER AND TRIM FOR ACCURATE ZERO.

2/ MAKE R3 & R13 10K ohm TO READ 10V = 1 mA AND 100K ohm TO READ 10V = 100 uA.

 

Download PDF

Download PDF :

 

 

HP Series | HPR Series | KS Series | Top

 

power supplies
power supply manufacturer
Power Supplies | Units by o/p Voltage | Company Profile | FAQ's | Contact | Careers | Site Map | Home