Input voltage:
|
24 volt d.c. ±10% at 7A.
Negative input terminal common to HV earth return.
|
|
HV Line regulation:
|
Less than 0.1% for input changes of 1 volt.
|
|
Voltage Control:
|
INTERNAL potentiometer or 10V analogue signal.
(0 to +10V gives zero to -50 kV output). Input impedance > 10 kohm.
|
|
Beam current control:
(Beam current stabilised.)
|
INTERNAL potentiometer or 10V analogue signal.
(0 to +10V gives 0 to 2 mA). Input impedance > 10 kohm.
|
|
Monitors:
|
Voltage 0 to +10V represents zero to -50 kV
(Accuracy ±3%, source resistance 10 kohm.)
Current 0 to +10V represents zero to 2 mA
(Accuracy ±5%, source resistance 10 kohm.)
Filament 0 to +10V represents zero to 3 Amps
(Accuracy ±10%, source resistance 10 kohm.)
|
|
Load regulation:
|
Less than 0.1% for load changes from 10% to maximum.
(Measured at maximum voltage).
|
|
On/Off:
|
Output voltage and heater slow rise to set levels when control pin is low (<1.5V).
|
|
Overload protection:
|
Flashover and short circuit proof.
Trip on over current (both HV & heater turn off) reset by on/off.
|
|
Temperature co-efficient:
|
300ppm per °C.
|
|
Operating temperature:
|
0 °C to +45 °C. Over temperature cut out.
|
|
Storage temperature:
|
-35 °C to +85 °C.
|
|
R.F.I.:
|
Choke input filter. Steel case for low radiated magnetic
field.
|
|
Safety:
|
Meets or exceeds requirements of EN61010-1.
|