power supplies, scientific instruments X-RAY Power Supplies
High Voltage Power Supplies
power supplies, photomultiplier tubes
PRODUCTS | COMPANY PROFILE | FAQ's | CAREERS | NEWS & EVENTS | SUPPORT | CONTACT US | HOME
 

 

Power Supplies with Floating Heater

 

XL025, XL030, XL035

50kV to 70kV 100W X-RAY Power Supplies with Floating Heater

High Voltage Section in OIL

X-RAY Power Supplies

Features :

  • Bipolar High Voltage Section for 70kV X-Ray Tubes
  • High Voltage Section mounts next to X-ray tube
  • Heater isolated to 35 kV 5V at 4 Amp
  • Short circuit and flashover proof
  • High efficiency, 24 hour burn in
  • Safety assessed to EN61010-1
  • Beam Current Control, stabilised by filament current.
  • Controlled turn-on. Minimises turn-on stress to tube and filament.
  • Stand-by Heater Current, set by internal potentiometer. 0-100%
  • Maximum Heater Current, set by internal potentiometer. 0-100%
  • Please contact the factory for special versions of this power supply.
  • LED Fault Diagnostics


The XL series is based on the HW, and XF series. It includes a 100W bipolar acceleration supply, and an isolated filament supply whose power is controlled to stabilise the beam current . It is intended to operate an X-ray tube in bipolar mode which minimises the voltage potentials with respect to Ground. The High Voltage section being mounted in the oil tank adjacent to the X-ray tube, eliminates the need for high voltage connectors. Control of the output voltage & current is by external 10 volt analogue control voltages. All units are short circuit proof and use high frequency pulse width modulated switching techniques, in conjunction with a ferrite step-up transformer to control the output voltage.

We manufacture a large number of customized OEM versions of this PSU, and would be pleased to discuss your application with you.


Electrical Specification

UNIT TYPE

OUTPUT VOLTAGE
Bipolar - +ve & -ve

X-Ray Tube Voltage

O/P RIPPLE

FILAMENT

   X L025BIP404

3kV to 25kV at 2mA

6kV to 50kV

<1%
peak to peak

4A @ 4V AC

Connected to HV -ve

   XL030BIP404

3.5kV to 30kV at 1.6mA  

7kV to 60kV

   XL035BIP404

4kV to 35kV at 1.4mA

8kV to 70kV

 

Input Voltage:

24 volt d.c. ±10% at 7A.
Negative input terminal common to HV earth return.

HV Line regulation:

Less than 0.1% for input changes of 1 volt.

Voltage Control:

10V analogue signal. Input impedance > 10 kohm.
(0 to +10V gives zero to max kV output ±5%.).

Beam current control:
(Beam current stabilised)

10V analogue signal. Input impedance > 10 kohm.
(0 to +10V gives 0 to full o/p).

Monitors:

Voltage 0 to +10V represents zero to max kV
(Accuracy ±3%, source resistance 10 kohm.)

Current 0 to +10V represents zero to max o/p current
(Accuracy ±5%, source resistance 10 kohm.)

Filament 0 to +10V represents zero to 4 Amps
(Accuracy ±10%, source resistance 10 kohm.)

Load regulation:

Less than 0.1% for load changes from 10% to maximum.
(Measured at maximum voltage).

On/Off:

Output voltage and filament slow rise to set levels when control pin is low (<1.5V). This also resets the trips.

Overload protection:

Flashover and short circuit proof.
Trip on over current (both HV & heater turn off) reset by on/off.

Temperature co-efficient:

300ppm per °C.

Operating Temperatur :

0°C to +45°C. 70°C over temperature cut out in oil.

Storage Temperatur:

-35°C to +85°C.

R.F.I.:

Choke input filter.

Safety:

Conforms to EN61010-1.

 

Mechanical Specification

Size:
HV In Oil Tank :
Low Voltage Plate:


260 x 125 x 80 mm
300 x 120 x 48 mm

Output:

By three 200mm 60kV cables

Power input connector:
Molex Sabre Series

PCB Mounted Straight Header: Molex Part no 43160-2102
Mates with Molex Part no 44441-2002 - RS part no 363-9875
Fitted with crimped terminals 43375-1001 - RS part no 364-0055

Control input connector:

Molex 0.1" 10 pin.

Connector Kit Order Code:

CONNECTORKITXF

 

LED Status Indication

Unit Enabled

Green

 

Low KV (<75% of demand)

Amber Warning

Red Trip

Low ma (<75% of demand)

Amber Warning

Red Trip

Overcurrent (>110% of Max)

Amber Warning

Red Trip

Over temperature

 

Red Trip

 

 

Download PDF

Download PDF:

Data Sheet | Installation Notes | Outline Drawing |


Top