| XL025, XL030, XL035
50kV to 70kV 100W X-RAY Power Supplies with Floating
Heater
High Voltage Section in OIL
|

|
Features :
- Bipolar High Voltage Section for 70kV X-Ray Tubes
- High Voltage Section mounts next to X-ray tube
- Heater isolated to 35 kV 5V at 4 Amp
- Short circuit and flashover proof
- High efficiency, 24 hour burn in
- Safety assessed to EN61010-1
- Beam Current Control, stabilised by filament current.
|
- Controlled turn-on. Minimises turn-on stress to tube
and filament.
- Stand-by Heater Current, set by internal potentiometer.
0-100%
- Maximum Heater Current, set by internal potentiometer.
0-100%
- Please contact the factory for special versions of this
power supply.
- LED Fault Diagnostics
|
|
|
The XL series is based on the HW, and XF
series. It includes a 100W bipolar acceleration supply, and an isolated
filament supply whose power is controlled to stabilise the beam
current . It is intended to operate an X-ray tube in bipolar mode
which minimises the voltage potentials with respect to Ground. The
High Voltage section being mounted in the oil tank adjacent to the
X-ray tube, eliminates the need for high voltage connectors. Control
of the output voltage & current is by external 10 volt analogue
control voltages. All units are short circuit proof and use high
frequency pulse width modulated switching techniques, in conjunction
with a ferrite step-up transformer to control the output voltage.
We manufacture a large number of customized OEM versions of this
PSU, and would be pleased to discuss your application with you.
|
Electrical Specification |
| UNIT TYPE |
OUTPUT VOLTAGE
Bipolar - +ve & -ve |
X-Ray Tube Voltage |
O/P RIPPLE |
FILAMENT |
| X L025BIP404 |
3kV to 25kV at 2mA |
6kV to 50kV |
<1%
peak to peak |
4A @ 4V AC
Connected to HV -ve |
| XL030BIP404 |
3.5kV to 30kV at 1.6mA |
7kV to 60kV |
| XL035BIP404 |
4kV to 35kV at 1.4mA |
8kV to 70kV |
|
| Input
Voltage: |
24 volt d.c. ±10%
at 7A.
Negative input terminal common to HV earth return. |
| HV Line regulation: |
Less than 0.1% for input changes of 1
volt. |
| Voltage
Control: |
10V analogue signal. Input impedance
> 10 kohm.
(0 to +10V gives zero to max kV output ±5%.). |
| Beam
current control:
(Beam current stabilised)
|
10V analogue signal.
Input impedance > 10 kohm.
(0 to +10V gives 0 to full o/p). |
|
Monitors: |
Voltage 0 to +10V represents zero to
max kV
(Accuracy ±3%, source resistance 10 kohm.)
Current 0 to +10V represents zero to max o/p current
(Accuracy ±5%, source resistance 10 kohm.)
Filament 0 to +10V represents zero to 4 Amps
(Accuracy ±10%, source resistance 10 kohm.) |
| Load regulation:
|
Less than 0.1% for load changes from
10% to maximum.
(Measured at maximum voltage). |
| On/Off: |
Output voltage and filament
slow rise to set levels when control pin is low (<1.5V).
This also resets the trips. |
| Overload
protection: |
Flashover and short circuit
proof.
Trip on over current (both HV & heater turn off) reset
by on/off. |
| Temperature
co-efficient:
|
300ppm per °C. |
| Operating
Temperatur : |
0°C to +45°C. 70°C
over temperature cut out in oil. |
| Storage
Temperatur: |
-35°C to +85°C. |
| R.F.I.: |
Choke input filter. |
Safety: |
Conforms to EN61010-1. |
|
Mechanical Specification |
| Size:
HV In Oil Tank :
Low Voltage Plate: |
260 x 125 x 80 mm
300 x 120 x 48 mm
|
| Output: |
By three 200mm 60kV cables |
Power input connector:
Molex Sabre Series
|
PCB Mounted Straight Header: Molex Part
no 43160-2102
Mates with Molex Part no 44441-2002 - RS part no 363-9875
Fitted with crimped terminals 43375-1001 - RS part no 364-0055 |
Control input connector: |
Molex 0.1" 10 pin. |
Connector Kit Order Code: |
CONNECTORKITXF |
|
LED Status Indication |
| Unit Enabled |
Green |
|
Low KV (<75% of demand) |
Amber Warning |
Red Trip |
Low ma (<75% of demand) |
Amber Warning |
Red Trip |
Overcurrent (>110% of Max)
|
Amber Warning |
Red Trip |
Over temperature |
|
Red Trip |
|
Top | Detailed Photo | Installation Notes
|