HX040, HX050

200W HIGH VOLTAGE MODULES

Applications :

X-Ray
Lasers
Capacitor charging
Ion Pumps
Ion implantation
Magnetrons

  • 40kV & 50kV
  • High efficiency
  • High frequency switch mode control
  • Internal control or externally programmable
  • Short circuit and flashover proof
  • 24 hour burn in
  • Safety assessed to EN61010-1
200W High Voltage Modules

[Click image to enlarge]


The 200 watt range HX series of high voltage modules covers the range from 40kV to 50 kV, they are particularly intended for X-ray applications. Control of the output voltage is by internal potentiometer, external potentiometer or by external 10 volt analogue control voltage. Control connections are by a 16 Way Ribbon. Please consult the factory if you require floating heater supplies for grounded target X-ray applications.

All units are short circuit proof and use high frequency pulse width modulated switching techniques, in conjunction with a ferrite step-up transformer to control the output voltage. The units operate from a 24 volt input and have an efficiency of around 80%. Please contact us to discuss special versions of these units.

Pin Connection & Safety Instructions | 100W HW Series Data Sheet


ELECTRICAL SPECIFICATION

UNIT TYPE

OUTPUT

RIPPLE AT FULL LOAD

 HX040PIS300

2 kV to 40 kV at 5 mA

Better than 1% peak to peak, measured with 200pf load capacitance

 HX040NIS300

-2kV to -40kV at 5mA 

 HX050PIS300

3 kV to 50 kV at 4 mA

 HX050NIS300

-3 kV to -50 kV at 4 mA



INPUT VOLTAGE:

+24 volt d.c. ±10% at 12A. Negative input terminal common to HV earth return.

LINE REGULATION:

Less than 0.1% for input changes of 1 volt.

LOAD REGULATION:

Less than 0.1% for load changes from 10% to maximum.
(Measured at maximum voltage).

OVERLOAD PROTECTION:

Flashover and short circuit proof.  Trip on over current, reset by on/off.

TEMPERATURE  CO-EFFICIENT:

300ppm/ °C or better. (consult factory for improved temperature coefficients).

CONTROL:

  • INTERNAL potentiometer.
  • EXTERNAL potentiometer
  • 10V analogue signal. (0 to +10V gives zero to maximum output, tolerance ±2%).Input impedance nominally 200Kohm.

READOUT:

Voltage monitor 0 to +10V represents zero to maximum output, tolerance ±3% (Source resistance 10 kohm).

Current monitor (option)0 to +10V ±7% represents zero to maximum current. (Source resistance 10 kohm).

N.B. Current monitor (supplied as standard) includes the internal feedback current of about 100uA. Precision I monitor (available as an option) removes this current to give a true reading of load current.

OPERATING TEMPERATURE:

0 °C to +45 °C

STORAGE TEMPERATURE:

-35 °C to +85 °C

R.F.I.:

Choke input filter.  Steel case for low radiated magnetic field.

SAFETY:

Complies with EN61010 Part 1



MECHANICAL SPECIFICATION

SIZE:

40kV units 280 x 170 x 60mm, 50kV unit 300 x 170 x 60mm

OUTPUT CABLE:

By 1 metre screened cable

INPUT CONNECTOR:

Molex (mating connector supplied). AK Order Code M12

ORDER CODE:
Series Code HX

o/p Voltage

Polarity

Options Code

Temp Co

040=40kV
050=50kV

P= +ve
N= -ve

IS = Stack Return Current Monitor
IP = Precision Current Monitor

300


e.g. 40kV Positive HX with the Stack Return Current Monitor (standard unit) is HX040PIS300

Please note that a constant current version of these units is not available. We expect this option to become available during 2005.

 