LS Series Data Sheet
LS001, LS2.5, LS005, LS010, LS015, LS020, LS030, LS050
PRECISION HIGH VOLTAGE MODULES
Applications : (1 Watt max)
- Mass spectrometers
- Electron microscopes
- Nuclear instruments
- Photomultiplier tubes
- Microchannel plates
|

[Click image to enlarge] |
- 1kV, 2.5kV, 5kV, 10kV, 15kV, 20kV, 30kV, 50kV
- Highest Stability, Lowest Ripple, Lowest Drift
- Externally programmable or Internal control (option)
|
- Short circuit and flashover proof
- 24 hour burn in
- Low radiated magnetic field
- Positive, negative & remote reversible versions
|
|
|
The LS Series sets a new standard for high voltage precision and
stability. By optimising the Low Stress™ technologies used
in our leading 10 Watt HP Series for 1 Watt applications, the new
LS Series has less than 1ppm ripple, 10ppm/°C temperature coefficient,
and 50ppm drift/hr throughout the range. Each of the units includes
a differential control input.
To take full advantage of the performance available from the
LS Range, they are initially only being made available to our OEM
customers as application specific, custom optimised, modules.
All units are short circuit proof and use proven techniques to
drive a high frequency oscillator and ferrite high voltage step-up
transformer. These advanced power supplies build on Applied Kilovolts'
legendary reputation for reliability, being constructed from conservatively
rated components with their reliability further enhanced by information
gained over many years of field operation.
Available as positive and negative units up to 50kV, and electrically
reversible at voltages up to 30kV.
Please see the HPZ range for zero crossing
reversible (bi-polar) units.
We manufacture a large number of customized OEM versions and would
be pleased to discuss your application with you.
|
Electrical Specification
Positive & Negative Polarity Units |
| UNIT TYPE |
POLARITY |
OUTPUT |
RIPPLE AT FULL LOAD |
SIZE (mm) |
| LS001PIP010 |
POSITIVE |
10 volts to
1kV at 1mA |
2mV peak to
peak |
156x127x64 |
| LS001NIP010 |
NEGATIVE |
| LS2.5PIP010 |
POSITIVE |
10 volts to
2.5kV at 400uA |
3mV peak to
peak |
156x127x64 |
| LS2.5NIP010 |
NEGATIVE |
| LS005PIP010 |
POSITIVE |
10 volts to
5kV at 200uA |
5mV peak to
peak |
156x127x64 |
| LS005NIP010 |
NEGATIVE |
|
LS010PIP010 |
POSITIVE |
20 volts to
10kV at 100uA |
10mV peak to
peak |
156x127x64 |
| LS010NIP010 |
NEGATIVE |
| LS015PIP010 |
POSITIVE |
30 volts to 15kV at 66.7uA |
15mV peak to
peak |
207x148x74 |
| LS015NIP010 |
NEGATIVE |
| LS020PIP010 |
POSITIVE |
50 volts to
20kV at 50uA |
20mV peak to
peak |
207x148x74 |
| LS020NIP010 |
NEGATIVE |
| LS030PIP010 |
POSITIVE |
100 volts to 30kV at 33.3uA |
30mV peak to
peak |
207x148x74 |
| LS030NIP010 |
NEGATIVE |
| LS050PIP010 |
POSITIVE |
200 volts to
50kV at 20uA |
50mV peak to
peak |
TBD |
| LS050NIP010 |
NEGATIVE |
|
Electrical Specification
REVERSIBLE POLARITY UNITS |
| UNIT TYPE |
POLARITY |
OUTPUT |
RIPPLE AT FULL LOAD |
SIZE (mm) |
| LS001RIP010 |
REVERSIBLE |
±10V to ±1kV
at 1mA |
2mV peak to peak |
163 x 152 x 71.5 |
| LS2.5RIP010 |
REVERSIBLE |
±10V to ±2.5kV
at 400uA |
3mV peak to peak |
163 x 152 x 71.5 |
| LS005RIP010 |
REVERSIBLE |
±10V to ±5kV
at 200uA |
5mV peak to peak |
163 x 152 x 71.5 |
| LS010RIP010 |
REVERSIBLE |
±20V to ±10kV
at 100uA |
10mV peak to peak |
163 x 152 x 71.5 |
| LS015RIP010 |
REVERSIBLE |
±30V to ±15kV
at 66.7uA |
15mV peak to peak |
233 x 204 x 114 |
| LS020RIP010 |
REVERSIBLE |
±50V to ±20kV
at 50uA |
20mV peak to peak |
233 x 204 x 114 |
| LS030RIP010 |
REVERSIBLE |
±100V to
±30kV at 33.3uA |
30mV peak to peak |
333 x 204 x 114 |
| Please see the HPZ
data sheet for continuously variable zero crossing power supplies.
LSR Data Sheet
|
|
| INPUT
VOLTAGE: |
+24 volt d.c. ±10%
at <150mA, for Unipolar, and at <200mA for Reversibles.
Negative input terminal common to HV earth return. |
| OUTPUT VOLTAGE: |
See tables above. |
| LINE
REGULATION: |
Less than 2ppm of maximum voltage for
input changes of 1 volt. |
| LOAD
REGULATION: |
Less than 2ppm for load changes from
10% to 100%.
(Measured at maximum voltage). |
| OVERLOAD PROTECTION: |
Flashover and short circuit proof. Re-entrant
current limit. |
| TEMPERATURE CO-EFFICIENT: |
<10ppm/°C from 20°C to 50°C |
| DRIFT: |
<50ppm per hour (<0.005%)
<100ppm per 8 hours (<0.01%)
Measured at constant input voltage, load current & ambient
temperature after 0.5 hour warm up. |
| CONTROL: |
10V analogue signal. (0 to
+10V gives zero to maximum output, tolerance ±2%).
Input impedance > 100Kohm.
EXTERNAL potentiometer = Option Code PP
INTERNAL potentiometer = Option Code FP |
| READOUT:
|
Voltage monitor :
0 to +10V represents zero to maximum output, tolerance ±2%
(Source resistance 10k).
Precision Current Monitor : 0 to 10V represents zero to
100% o/p current, tolerance ±2%, Offset ±0.1%
of FS.
|
| OPERATING
TEMPERATURE: |
0°C to +50°C |
| STORAGE
TEMPERATURE: |
-35°C to +85°C |
| R.F.I.: |
Steel case for low radiated
magnetic field. |
|
Mechanical Specification |
| FIXINGS: |
Blind Fasteners front and
rear. |
| OUTPUT: |
By 1 metre screened cable,
or optional integrated high voltage connector
N.B. Reducing the cable length may increase the ripple voltage. |
INPUT CONNECTOR: |
15 way D-type |
|
Order Code:
LS010NIP010 = negative 10kV unit
LS005PPP010 = positive 5kV unit for control by External Potentiometer.
Top | Detailed Photo | LS
Safety Instructions | LSR Safety Instructions
|