power supplies, scientific instruments scientific instruments
High Voltage Power Supplies
power supplies, photomultiplier tubes
PRODUCTS | COMPANY PROFILE | FAQ's | CAREERS | NEWS & EVENTS | SUPPORT | CONTACT US | HOME
 

 

Precision high voltage modules

 

LS Series Data Sheet
LS001, LS2.5, LS005, LS010, LS015, LS020, LS030, LS050

PRECISION HIGH VOLTAGE MODULES

Applications : (1 Watt max)

- Mass spectrometers
- Electron microscopes
- Nuclear instruments
- Photomultiplier tubes
- Microchannel plates

Precision high voltage power supply modules

[Click image to enlarge]


  • 1kV, 2.5kV, 5kV, 10kV, 15kV, 20kV, 30kV, 50kV
  • Highest Stability, Lowest Ripple, Lowest Drift
  • Externally programmable or Internal control (option)
  • Short circuit and flashover proof
  • 24 hour burn in
  • Low radiated magnetic field
  • Positive, negative & remote reversible versions


The LS Series sets a new standard for high voltage precision and stability. By optimising the Low Stress™ technologies used in our leading 10 Watt HP Series for 1 Watt applications, the new LS Series has less than 1ppm ripple, 10ppm/°C temperature coefficient, and 50ppm drift/hr throughout the range. Each of the units includes a differential control input.

To take full advantage of the performance available from the LS Range, they are initially only being made available to our OEM customers as application specific, custom optimised, modules.

All units are short circuit proof and use proven techniques to drive a high frequency oscillator and ferrite high voltage step-up transformer. These advanced power supplies build on Applied Kilovolts' legendary reputation for reliability, being constructed from conservatively rated components with their reliability further enhanced by information gained over many years of field operation.

Available as positive and negative units up to 50kV, and electrically reversible at voltages up to 30kV. Please see the HPZ range for zero crossing reversible (bi-polar) units.

We manufacture a large number of customized OEM versions and would be pleased to discuss your application with you.


Electrical Specification
Positive & Negative Polarity Units

UNIT TYPE

POLARITY

OUTPUT

RIPPLE AT FULL LOAD

SIZE (mm)

   LS001PIP010

POSITIVE

10 volts to 1kV at 1mA

2mV peak to peak

156x127x64

   LS001NIP010

NEGATIVE

   LS2.5PIP010

POSITIVE

10 volts to 2.5kV at 400uA

3mV peak to peak

156x127x64

   LS2.5NIP010

NEGATIVE

   LS005PIP010

POSITIVE

10 volts to 5kV at 200uA

5mV peak to peak

156x127x64

   LS005NIP010

NEGATIVE

   LS010PIP010

POSITIVE

20 volts to 10kV at 100uA

10mV peak to peak

156x127x64

   LS010NIP010

NEGATIVE

   LS015PIP010

POSITIVE

30 volts to 15kV at 66.7uA

15mV peak to peak

207x148x74

   LS015NIP010

NEGATIVE

   LS020PIP010

POSITIVE

50 volts to 20kV at 50uA

20mV peak to peak

207x148x74

   LS020NIP010

NEGATIVE

   LS030PIP010

POSITIVE

100 volts to 30kV at 33.3uA

30mV peak to peak

207x148x74

   LS030NIP010

NEGATIVE

   LS050PIP010

POSITIVE

200 volts to 50kV at 20uA

50mV peak to peak

TBD

   LS050NIP010

NEGATIVE


Electrical Specification
REVERSIBLE POLARITY UNITS

UNIT TYPE

POLARITY

OUTPUT

RIPPLE AT FULL LOAD

SIZE (mm)

   LS001RIP010

REVERSIBLE

±10V to ±1kV at 1mA

2mV peak to peak

163 x 152 x 71.5

   LS2.5RIP010

REVERSIBLE

±10V to ±2.5kV at 400uA

3mV peak to peak

163 x 152 x 71.5

   LS005RIP010

REVERSIBLE

±10V to ±5kV at 200uA

5mV peak to peak

163 x 152 x 71.5

   LS010RIP010

REVERSIBLE

±20V to ±10kV at 100uA

10mV peak to peak

163 x 152 x 71.5

   LS015RIP010

REVERSIBLE

±30V to ±15kV at 66.7uA

15mV peak to peak

233 x 204 x 114

   LS020RIP010

REVERSIBLE

±50V to ±20kV at 50uA

20mV peak to peak

233 x 204 x 114

   LS030RIP010

REVERSIBLE

±100V to ±30kV at 33.3uA

30mV peak to peak

333 x 204 x 114

Please see the HPZ data sheet for continuously variable zero crossing power supplies.

LSR Data Sheet

 

INPUT VOLTAGE:

+24 volt d.c. ±10% at <150mA, for Unipolar, and at <200mA for Reversibles. Negative input terminal common to HV earth return.

OUTPUT VOLTAGE:

See tables above.

LINE REGULATION:

Less than 2ppm of maximum voltage for input changes of 1 volt.

LOAD REGULATION:

Less than 2ppm for load changes from 10% to 100%.
(Measured at maximum voltage).

OVERLOAD PROTECTION:

Flashover and short circuit proof. Re-entrant current limit.

TEMPERATURE CO-EFFICIENT:

<10ppm/°C from 20°C to 50°C

DRIFT:

<50ppm per hour (<0.005%)
<100ppm per 8 hours (<0.01%)
Measured at constant input voltage, load current & ambient temperature after 0.5 hour warm up.

CONTROL:

10V analogue signal. (0 to +10V gives zero to maximum output, tolerance ±2%). Input impedance > 100Kohm.
EXTERNAL potentiometer = Option Code PP
INTERNAL potentiometer = Option Code FP

READOUT:

Voltage monitor : 0 to +10V represents zero to maximum output, tolerance ±2% (Source resistance 10k).
Precision Current Monitor :
0 to 10V represents zero to 100% o/p current, tolerance ±2%, Offset ±0.1% of FS.

OPERATING TEMPERATURE:

0°C to +50°C

STORAGE TEMPERATURE:

-35°C to +85°C

R.F.I.:

Steel case for low radiated magnetic field.

 

Mechanical Specification

FIXINGS:

Blind Fasteners front and rear.

OUTPUT:

By 1 metre screened cable, or optional integrated high voltage connector
N.B. Reducing the cable length may increase the ripple voltage.

INPUT CONNECTOR:

15 way D-type


Order Code:
LS010NIP010 = negative 10kV unit
LS005PPP010 = positive 5kV unit for control by External Potentiometer.