Manufacturer of high voltage power supplies Applied Kilovolts
High Voltage Power Supplies
power supplies
PRODUCTS | COMPANY PROFILE | FAQ's | CAREERS | NEWS & EVENTS | SUPPORT | CONTACT US | HOME
 
Reversible High Voltage Modules

 

RD005kV, RD7.5kV, RD010kV, RD012kV

Reversible High Voltage Modules + Floating 3kV Detector Supply.

Applications :

  • TOF Mass Spectrometers
  • Floating Detectors

Reversible High Voltage Modules

[Click image to enlarge]


Pin Connection & Safety Instructions

 

Electrical Specification

UNIT TYPE

BIAS OUTPUT

RIPPLE AT FULL LOAD

FLOATING DETECTOR

   RD005RIP025

-5 kV to +5 kV at 250uA

150mV peak to peak

3Kv @ 400uA <200mV Ripple

   RD7.5RIP025

-7.5 kV to +7.5 kV at 150uA

165mV peak to peak

3Kv @ 400uA <200mV Ripple

   RD010RIP025

-10 kV to +10 kV at 125uA

200mV peak to peak

3Kv @ 400uA <200mV Ripple

   RD012RIP025

-12.5 kV to +12.5 kV at 150uA

200mV peak to peak

3Kv @ 400uA <200mV Ripple

 

Input voltages:

+24 V ±10% at 1A.

Bias Output voltage:

See table above. Joined within the unit to Detector -ve

Bias Control voltage:

0V to +10 V gives 0V to max. kV ±2%.
nb: Internal manual potentiometer control not fitted.

Load regulation:

Less than 100 ppm for zero to max. load.

Line regulation:

Less than 100 ppm for 1V change in I/P volts.

V monitor:

0 to ±10V represents 0 to ±max o/p voltage, ±2% output impedance 10 kohm.

I monitor:

0 to ±10V represents 0 to ±max o/p current, ±5% output impedance 10 kohm.

Speed of reversing:

< 500 mS.

Temperature Co-efficient:

<25 ppm per °C. (<10ppm per °C available shortly)

Detector Control Voltage:

0V to +10 V gives 0V to 3 kV ±5%.

Minimum Detector O/P V:

500V

Detector Vmon:

0 to 10 V represents 0 to 3kV o/p voltage, output impedance 10 kohm.

Detector Load regulation:

< 0.1% for zero to max. load.

Detector Line regulation:

< 0.1% for 1V change in I/P volts.

Detector Temp-co:

<300 ppm per °C.

Operating temperature:

0 °C to +45 °C.

 

Mechanical Specification

Size:

240 x 216 x 100mm. nb.Grounding of the case is via fixing bolts.

Output Cables:

URM43 length 0.5 metre. Labelled Detector Minus, & Detector Plus

Input connector:

BERG 20 Way IDC header.

Compliance:

Designed to meet or exceed EN61010.



Download PDF

Download PDF:

Data Sheet | Installation Notes | Outline Drawing |

 

Top | Pin Connections | Detailed Photo

 